Traction Type |
|
Bitmap
Demensions of Hoistway M/C Room Section (unit : mm) | |
|
Speed |
Overhead |
Pit Depth |
M/C Room |
|
|
|
|
|
|
(m/min) |
(O.H) |
(P) |
Height(M.H) |
|
|
|
|
|
|
30,45 |
4450 |
1250 |
2500 |
|
|
|
|
|
|
60 |
4650 |
1550 |
|
|
|
|
|
|
|
|
Bitmap
|
|
Speed |
Type |
Clear |
Car Internal |
Shaft Internal |
Machine Room |
M/C Room |
Impact Load |
(m/min) |
Opening |
Demension |
Dimension |
Internal |
Reaction |
on the Pit |
|
(MAX) |
(mm) |
(mm) |
Dimension |
(kg) |
(kg) |
|
(mm) |
|
|
(mm) |
|
|
|
|
|
X X Y |
MA X MB |
|
|
|
W X H |
A X B |
R1 |
R2 |
Car side |
Cwt side |
|
(p1) |
(P2) |
30 |
C2000-2U,3U |
2350X |
2350X |
3500X |
5500X |
13500 / 14400 |
9000 / |
15500/ |
12600/ |
45 |
1800 |
5250 |
6000 |
6000 |
9600 |
21100 |
17300 |
60 |
C2500-2U,3U |
2750X |
2750X |
3900X |
5900X |
16400 / 17500 |
10800/ |
19500/ |
15700/ |
|
1800 |
6150 |
6900 |
6900 |
11700 |
25500 |
20500 |
|
※ Notes 1. It is required to install the ventilation fan and grille in machine room |
considering of heat generation and maintenance conveniences. |
2. As the hoistway inside dimensions shown on the table are the minimum size, |
some allowance are required considering the slope of the hoistways. |
3. It is also required any prior confirmation in the event of using the forklift. |
(Any technical information of forklift in use at your company is required) |
4. The calculating formula(mm) of Minimum floor Height. |
· 2u → H x 1.5 + 600 <= Minimum floor Height |
· 3u → H x 4/3 + 600 <= Minimum floor Height |
∴ H : The height of the entrancle door |
5. The internal car size of two-way entrance car type should be confirmed us |
as it is quite different from the standard dimension of the hoistway. |
|
|
Indirect Roped Plunger Type |
|
Bitmap
Dimensions of Hoistway and M/C Room Section (unit : mm) | |
|
Overhead |
Pit Depth |
M/C Room |
Travel(T.R) |
|
|
|
|
|
|
(m/min) |
(P) |
Height(M.H) |
(MAX) |
|
|
|
|
|
|
4100 |
1250 |
2100 |
20000 |
|
|
|
|
|
|
|
|
Bitmap
Dimensions of Hoistway and M/C Room | |
|
Speed |
Type |
Capacity |
Clear |
Car Internal |
Shaft Internal |
Machine Room Internal |
Impact Load on the Pit(kg) |
|
(m/min) |
(kg) |
Opening(MAX) |
Demension |
Dimension(mm) |
Dimension(mm) |
|
|
|
(mm) |
(mm) |
X X Y |
MA X MB |
|
|
|
W X H |
A X B |
Car side(p1) |
Cylinder side(P2) |
|
15 |
HIC2000-2U,3U |
2000 |
2350 X 1800 |
2350 x 5250 |
3600 X 6000 |
2350 x 4500 |
9000 |
8100 |
|
|
|
20 |
HIC2500-2U,3U |
2500 |
2750 X 1800 |
2750 x 6150 |
4000 X 6900 |
2300 x 4500 |
10500 |
9900 |
|
|
※ Notes 1. It is desirable that the machine room is locating at the lowest floor within 10 |
meters from the sides of the hoistway. |
2. The calculating formula(mm) of Minimum floor Height. |
· 2u → H x 1.5 +600 <= Minimum floor Height |
· 3u → H x 4/3 + 600 <= Minimum floor Height |
∴ H : The height of the entrancle door |
3. It is required to install the ventilation fan and grille in machine room |
considering of heat generation and maintenance conveniences. |
4. It is also required any prior confirmation in the event of using the forklift. |
(Any technical information of forklift in use at your company is required) |
5. The internal car size of two-way entrance car type should be confirmed us |
as it is quite different from the standard dimension of the hoistway. |